Re: s6-svscan & SIGPWR

From: Brian Shore <brian_at_networkredux.com>
Date: Mon, 14 Mar 2016 11:45:56 -0700

On Mon, Mar 14, 2016 at 11:18 AM, Laurent Bercot
<ska-supervision_at_skarnet.org> wrote:
> The correct workaround is indeed to use the -s option to s6-svscan and
> write appropriate .s6-svscan/SIG* scripts to handle various signals in a
> personalized way.

Alternatively, change LXC's behavior via the configuraiton file. We
use the following with runit (which expects SIGCONT for shutdown):

lxc.haltsignal = SIGCONT
lxc.stopsignal = SIGCONT


-- 
Brian Shore
Senior Systems Engineer, Security Architect
Network Redux, LLC
5200 SW Macadam Ave Ste 450
Portland, Oregon 97239
Desk:  503-274-9905 x503
Received on Mon Mar 14 2016 - 18:45:56 UTC